Titanium Plate을 사용하여 복합안와골절 정복술 후 25년이 지나서 발생한 합병증 1예

김도현1, 임준식1, 권기승1, 한정욱1,*
Do Hyun Kim1, Jun Sick Im1, Ki Seung Kwon1, Jung Uk Han1,*
1메리놀병원 이비인후과
1Department of Otorhinolaryngology, Maryknoll Hospital, Busan, Korea
*교신저자: 한정욱, 600-730 부산광역시 중구로 121 메리놀병원 이비인후과 전화 :(051) 465-2205·전송:(051) 462-9419 E-mail:hju0617@nate.com

© Copyright 2015 The Busan, Ulsan, Gyeoungnam Branch of Korean Society of Otolaryngology-Head and Neck Surgery. This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Received: Feb 27, 2015; Revised: Apr 08, 2015; Accepted: May 23, 2015

Published Online: May 31, 2020

ABSTRACT

Recently there is an increasing trend of facial fracture, especially complex fractures. These complex facial fractures need implant for optimal treatment. Titanium is the most commonly used material, but there are few reports of complications after 10 years of implantation. The authors report a case of delayed complication of titanium implant in complex orbital wall fracture in a 69-year-old man. (J Clinical Otolaryngol 2015;26:96-99)

Keywords: 인공 삽입물; 골절; 합병증
Keywords: Titanium; Fractures; Postoperative complications